Hardware Management Console Best Practices
- 33 -
7310-C03 desktop model, or 7310-CR2 / 7310-CR3 rack-mount models, make
sure the hyperthreading option under the Advanced options in BIOS is disabled.
On these models, this can be verified on the command line as user root by
typing:
dmesg | grep -i hyper
There will be no output if hyper threading is disabled.
Performance can suffer if trace and log files fill the HMC file system. Disk space
usage can be checked by typing (only as user root!) df –h . If any
filesystem partition is in 100% use, your service provider should be consulted.
The managed systems and frames can be in one of many states, as reported by the
HMC. A description of managed system states can be found at:
http://publib.boulder.ibm.com/infocenter/iseries/v1r2s/en_US/info/ipha1/poweron
states.htm,
A description of frame states can be found at:
http://publib.boulder.ibm.com/infocenter/iseries/v1r2s/en_US/info/ipha1/framepo
weronstates.htm.
Among the states that cause confusion:
No Connection: The HMC cannot build a valid connection to the FSP / BPC.
The reason will be displayed as an error code under the Op Panel value column
on the GUI. If you believe that this state has been reached in error, you can
reset the network connection between the HMC and FSP. By right-clicking on
the managed system to bring up the pop-up menu, or selecting the managed
system and going to the ‘Selected’ menu, select ‘Reset or Remove’ Connection
on the HMC Console. You must have task role hmcsuperadmin,
hmcoperator, or hmcpe to perform this operation. You can also initiate
this task from the command line: rmsysconn command with –o reset flag.
Definitions for No Connection codes, as well as corrective measures that can be
taken, can be found at
http://publib.boulder.ibm.com/infocenter/iseries/v1r2s/en_US/info/ipha5/hmc_c
odes_0.htm
.