Vista de pagina 34
Hardware Management Console Best Practices
- 35 -
Another observed problem has been the GUI isn’t reflecting the true managed
system or frame status or configuration. The CLI can be used to see if it gives up-
to-date information. If so, this means the GUI has either stopped receiving
indication data, or no indications are being propagated to it. A Reload (F5) can
refresh the GUI in this situation. If the command line is also incorrect, the HMC
has stopped receiving event notifications from the managed system or frame. To
recovery from this situation, perform the Rebuild Managed System task.
The FSP provides the HMC with the capability to set locks on the platform. The
FSP does not interpret the locks, but rather leaves it up to the HMC functions to
do that. These locks are used for synchronization of operations from one or two
(dual) HMCs. In a dual HMC environment, situations can arise where both
HMCs perform tasks against the same managed system and require the same lock.
When HMC 2 needs to perform a task that requires a lock that HMC 1 is currently
holding, HMC 2 will wait and retry to acquire the lock. If after a few attempts it
is unsuccessful, the operation will fail and the user will be notified accordingly.
Often this blocked state can be mistaken for a “hang,” when that in fact is not the
case. However, it is possible for HMC 1 to acquire a lock and fail to release it.
Should this happen, HMC 2 can be used to disconnect HMC 1. When an HMC is
disconnected, all locks owned by the HMC are reset. To due this, any
hmcsuperadmin user can run the ‘Disconnect Another HMC’ GUI task on
HMC 2 against HMC1. This can only be done from the graphical interface. There
is no corresponding command line version of this task.